Cold-formed RHS

120x60x6.0

Standard: BS EN 10219-2Source: Calculated — radii per EN 10219-2
xyb = 60d = 120t = 6t = 6
Cross-section, to scaledimensions in mm

Dimensions

Depthd
120mm
Widthb
60mm
Thicknesst
6mm
Outside corner radiusro
12mm

Mass and area

Mass per lengthm
15.1kg/m
Cross-sectional areaA
1,923mm²
Outside perimeterP
339.4mm

Strong axis x–x

Moment of inertiaIx
3.2810⁶ mm⁴
Elastic section modulusSx
54.6710³ mm³
Plastic section modulusZx
70.5710³ mm³
Radius of gyrationrx
41.3mm

Weak axis y–y

Moment of inertiaIy
1.08810⁶ mm⁴
Elastic section modulusSy
36.2610³ mm³
Plastic section modulusZy
43.1210³ mm³
Radius of gyrationry
23.78mm

Torsion and stability

Torsional constantJ
2,79710³ mm⁴