UC – universal columns

150UC23.4

Standard: AS/NZS 3679.1Source: InfraBuild dimensions, Hot Rolled & Structural Steel Products (ed. 9) — calculated properties
Same sections as Australia (joint AS/NZS standard). Published area (Ag) shown as a check: difference < 1.5% on every section.
xybf = 152d = 152.4tf = 6.8tf = 6.8tw = 6.1tw = 6.1
Cross-section, to scaledimensions in mm

Dimensions

Depthd
152.4mm
Flange widthbf
152mm
Web thicknesstw
6.1mm
Flange thicknesstf
6.8mm
Root radiusr
8.9mm

Mass and area

Mass per lengthm
23.41kg/m
Cross-sectional areaA
2,982mm²
Published area (standard)A pub.
2,980mm²
Outside perimeterP
885.3mm

Strong axis x–x

Moment of inertiaIx
12.6310⁶ mm⁴
Elastic section modulusSx
165.810³ mm³
Plastic section modulusZx
184.510³ mm³
Radius of gyrationrx
65.09mm

Weak axis y–y

Moment of inertiaIy
3.98510⁶ mm⁴
Elastic section modulusSy
52.4310³ mm³
Plastic section modulusZy
80.1910³ mm³
Radius of gyrationry
36.56mm

Torsion and stability

Torsional constantJ
53.9610³ mm⁴
Warping constantCw
21.0910⁹ mm⁶