UC – universal columns

250UC72.9

Standard: AS/NZS 3679.1Source: InfraBuild dimensions, Hot Rolled & Structural Steel Products (ed. 9) — calculated properties
Same sections as Australia (joint AS/NZS standard). Published area (Ag) shown as a check: difference < 1.5% on every section.
xybf = 254d = 253.8tf = 14.2tf = 14.2tw = 8.6tw = 8.6
Cross-section, to scaledimensions in mm

Dimensions

Depthd
253.8mm
Flange widthbf
254mm
Web thicknesstw
8.6mm
Flange thicknesstf
14.2mm
Root radiusr
14mm

Mass and area

Mass per lengthm
73.16kg/m
Cross-sectional areaA
9,320mm²
Published area (standard)A pub.
9,320mm²
Outside perimeterP
1,482mm

Strong axis x–x

Moment of inertiaIx
113.910⁶ mm⁴
Elastic section modulusSx
897.410³ mm³
Plastic section modulusZx
991.910³ mm³
Radius of gyrationrx
110.5mm

Weak axis y–y

Moment of inertiaIy
38.8110⁶ mm⁴
Elastic section modulusSy
305.610³ mm³
Plastic section modulusZy
463.510³ mm³
Radius of gyrationry
64.53mm

Torsion and stability

Torsional constantJ
586.410³ mm⁴
Warping constantCw
556.610⁹ mm⁶

Equivalents in other standards