Tracks (T)

1000T200-54

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 2d = 10.11t = 0.0566t = 0.0566
Cross-section, to scaledimensions in inches

Dimensions

Depthd
10.11in
Flange widthbf
2in
Thicknesst
0.0566in
Inside bend radiusri
0.08488in

Mass and area

Mass per lengthm
2.678lb/ft
Cross-sectional areaA
0.7869in²
Outside perimeterP
27.92in

Strong axis x–x

Moment of inertiaIx
10.3in⁴
Elastic section modulusSx
2.037in³
Plastic section modulusZx
2.526in³
Radius of gyrationrx
3.618in

Weak axis y–y

Moment of inertiaIy
0.2278in⁴
Elastic section modulusSy
0.1346in³
Plastic section modulusZy
0.2268in³
Radius of gyrationry
0.5381in

Torsion and stability

Torsional constantJ
0.0008369in⁴

Centers

Centroidx̄
0.308in

Equivalents in other standards