Tracks (T)

250T200-54

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 2d = 2.613t = 0.0566t = 0.0566
Cross-section, to scaledimensions in inches

Dimensions

Depthd
2.613in
Flange widthbf
2in
Thicknesst
0.0566in
Inside bend radiusri
0.08488in

Mass and area

Mass per lengthm
1.233lb/ft
Cross-sectional areaA
0.3624in²
Outside perimeterP
12.92in

Strong axis x–x

Moment of inertiaIx
0.4344in⁴
Elastic section modulusSx
0.3325in³
Plastic section modulusZx
0.3707in³
Radius of gyrationrx
1.095in

Weak axis y–y

Moment of inertiaIy
0.1556in⁴
Elastic section modulusSy
0.114in³
Plastic section modulusZy
0.2044in³
Radius of gyrationry
0.6552in

Torsion and stability

Torsional constantJ
0.0003836in⁴

Centers

Centroidx̄
0.6357in

Equivalents in other standards