Tracks (T)

400T200-33

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 2d = 4.069t = 0.0346t = 0.0346
Cross-section, to scaledimensions in inches

Dimensions

Depthd
4.069in
Flange widthbf
2in
Thicknesst
0.0346in
Inside bend radiusri
0.07642in

Mass and area

Mass per lengthm
0.9325lb/ft
Cross-sectional areaA
0.274in²
Outside perimeterP
15.91in

Strong axis x–x

Moment of inertiaIx
0.7363in⁴
Elastic section modulusSx
0.3619in³
Plastic section modulusZx
0.4119in³
Radius of gyrationrx
1.639in

Weak axis y–y

Moment of inertiaIy
0.1122in⁴
Elastic section modulusSy
0.07553in³
Plastic section modulusZy
0.136in³
Radius of gyrationry
0.64in

Torsion and stability

Torsional constantJ
0.0001089in⁴

Centers

Centroidx̄
0.5138in

Equivalents in other standards