Tracks (T)

400T200-54

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 2d = 4.113t = 0.0566t = 0.0566
Cross-section, to scaledimensions in inches

Dimensions

Depthd
4.113in
Flange widthbf
2in
Thicknesst
0.0566in
Inside bend radiusri
0.08488in

Mass and area

Mass per lengthm
1.522lb/ft
Cross-sectional areaA
0.4473in²
Outside perimeterP
15.92in

Strong axis x–x

Moment of inertiaIx
1.21in⁴
Elastic section modulusSx
0.5885in³
Plastic section modulusZx
0.6743in³
Radius of gyrationrx
1.645in

Weak axis y–y

Moment of inertiaIy
0.181in⁴
Elastic section modulusSy
0.1223in³
Plastic section modulusZy
0.2201in³
Radius of gyrationry
0.6361in

Torsion and stability

Torsional constantJ
0.0004742in⁴

Centers

Centroidx̄
0.5204in

Equivalents in other standards