Tracks (T)

600T125-43

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 1.25d = 6.09t = 0.0451t = 0.0451
Cross-section, to scaledimensions in inches

Dimensions

Depthd
6.09in
Flange widthbf
1.25in
Thicknesst
0.0451in
Inside bend radiusri
0.07118in

Mass and area

Mass per lengthm
1.292lb/ft
Cross-sectional areaA
0.3797in²
Outside perimeterP
16.93in

Strong axis x–x

Moment of inertiaIx
1.808in⁴
Elastic section modulusSx
0.5939in³
Plastic section modulusZx
0.7357in³
Radius of gyrationrx
2.182in

Weak axis y–y

Moment of inertiaIy
0.04348in⁴
Elastic section modulusSy
0.04147in³
Plastic section modulusZy
0.07049in³
Radius of gyrationry
0.3384in

Torsion and stability

Torsional constantJ
0.0002561in⁴

Centers

Centroidx̄
0.2016in