HE A – wide flange, light series

HEA 900

Standard: EN 10365:2017Source: Geometry: Steel Section Database (MIT) — calculated properties (exact engine)
xybf = 300d = 890tf = 30tf = 30tw = 16tw = 16
Cross-section, to scaledimensions in mm

Dimensions

Depthd
890mm
Flange widthbf
300mm
Web thicknesstw
16mm
Flange thicknesstf
30mm
Root radiusr
30mm

Mass and area

Mass per lengthm
251.6kg/m
Cross-sectional areaA
32,053mm²
Outside perimeterP
2,897mm

Strong axis x–x

Moment of inertiaIx
4,22110⁶ mm⁴
Elastic section modulusSx
9,48510³ mm³
Plastic section modulusZx
10,81110³ mm³
Radius of gyrationrx
362.9mm

Weak axis y–y

Moment of inertiaIy
135.510⁶ mm⁴
Elastic section modulusSy
903.210³ mm³
Plastic section modulusZy
1,41410³ mm³
Radius of gyrationry
65.01mm

Torsion and stability

Torsional constantJ
7,36810³ mm⁴
Warping constantCw
24,96210⁹ mm⁶

Equivalents in other standards