IPN – tapered flanges

IPN 120

Standard: EN 10365:2017Source: Geometry: Steel Section Database (MIT) — calculated properties (exact engine)
xybf = 58d = 120tf = 7.7tf = 7.7tw = 5.1tw = 5.1
Cross-section, to scaledimensions in mm

Dimensions

Depthd
120mm
Flange widthbf
58mm
Web thicknesstw
5.1mm
Flange thicknesstf
7.7mm
Root radiusr1
5.1mm
Toe radiusr2
3.1mm

Mass and area

Mass per lengthm
11.13kg/m
Cross-sectional areaA
1,418mm²
Outside perimeterP
437.9mm

Strong axis x–x

Moment of inertiaIx
3.27110⁶ mm⁴
Elastic section modulusSx
54.5110³ mm³
Plastic section modulusZx
63.5310³ mm³
Radius of gyrationrx
48.03mm

Weak axis y–y

Moment of inertiaIy
0.213910⁶ mm⁴
Elastic section modulusSy
7.37710³ mm³
Plastic section modulusZy
12.3610³ mm³
Radius of gyrationry
12.28mm