UPE – parallel-flange channels

UPE 120

Standard: EN 10365:2017Source: Geometry: Steel Section Database (MIT) — calculated properties (exact engine)
xybf = 60d = 120tf = 8tf = 8tw = 5tw = 5
Cross-section, to scaledimensions in mm

Dimensions

Depthd
120mm
Flange widthbf
60mm
Web thicknesstw
5mm
Flange thicknesstf
8mm
Root radiusr
12mm

Mass and area

Mass per lengthm
12.1kg/m
Cross-sectional areaA
1,542mm²
Outside perimeterP
459.7mm

Strong axis x–x

Moment of inertiaIx
3.63510⁶ mm⁴
Elastic section modulusSx
60.5810³ mm³
Plastic section modulusZx
70.3310³ mm³
Radius of gyrationrx
48.56mm

Weak axis y–y

Moment of inertiaIy
0.55410⁶ mm⁴
Elastic section modulusSy
13.7910³ mm³
Plastic section modulusZy
24.810³ mm³
Radius of gyrationry
18.96mm

Torsion and stability

Torsional constantJ
28.9910³ mm⁴

Centers

Centroidx̄
19.83mm

Equivalents in other standards