UPE – parallel-flange channels

UPE 400

Standard: EN 10365:2017Source: Geometry: Steel Section Database (MIT) — calculated properties (exact engine)
xybf = 115d = 400tf = 18tf = 18tw = 13.5tw = 13.5
Cross-section, to scaledimensions in mm

Dimensions

Depthd
400mm
Flange widthbf
115mm
Web thicknesstw
13.5mm
Flange thicknesstf
18mm
Root radiusr
18mm

Mass and area

Mass per lengthm
72.17kg/m
Cross-sectional areaA
9,193mm²
Outside perimeterP
1,218mm

Strong axis x–x

Moment of inertiaIx
209.810⁶ mm⁴
Elastic section modulusSx
1,04910³ mm³
Plastic section modulusZx
1,26310³ mm³
Radius of gyrationrx
151.1mm

Weak axis y–y

Moment of inertiaIy
10.4510⁶ mm⁴
Elastic section modulusSy
122.610³ mm³
Plastic section modulusZy
220.810³ mm³
Radius of gyrationry
33.71mm

Torsion and stability

Torsional constantJ
791.410³ mm⁴

Centers

Centroidx̄
29.77mm

Equivalents in other standards