Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 1.25d = 5.613t = 0.0566t = 0.0566
Cross-section, to scaledimensions in inches

Dimensions

Depthd
5.613in
Flange widthbf
1.25in
Thicknesst
0.0566in
Inside bend radiusri
0.08488in

Mass and area

Mass per lengthm
1.522lb/ft
Cross-sectional areaA
0.4473in²
Outside perimeterP
15.92in

Strong axis x–x

Moment of inertiaIx
1.834in⁴
Elastic section modulusSx
0.6534in³
Plastic section modulusZx
0.8058in³
Radius of gyrationrx
2.025in

Weak axis y–y

Moment of inertiaIy
0.05291in⁴
Elastic section modulusSy
0.05123in³
Plastic section modulusZy
0.08802in³
Radius of gyrationry
0.3439in

Torsion and stability

Torsional constantJ
0.0004742in⁴

Centers

Centroidx̄
0.2173in

Equivalents in other standards