Tracks (T)

550T125-68

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 1.25d = 5.643t = 0.0713t = 0.0713
Cross-section, to scaledimensions in inches

Dimensions

Depthd
5.643in
Flange widthbf
1.25in
Thicknesst
0.0713in
Inside bend radiusri
0.1069in

Mass and area

Mass per lengthm
1.911lb/ft
Cross-sectional areaA
0.5617in²
Outside perimeterP
15.9in

Strong axis x–x

Moment of inertiaIx
2.303in⁴
Elastic section modulusSx
0.8162in³
Plastic section modulusZx
1.011in³
Radius of gyrationrx
2.025in

Weak axis y–y

Moment of inertiaIy
0.06556in⁴
Elastic section modulusSy
0.06384in³
Plastic section modulusZy
0.1108in³
Radius of gyrationry
0.3416in

Torsion and stability

Torsional constantJ
0.0009432in⁴

Centers

Centroidx̄
0.2231in

Equivalents in other standards