Tracks (T)

550T200-33

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 2d = 5.569t = 0.0346t = 0.0346
Cross-section, to scaledimensions in inches

Dimensions

Depthd
5.569in
Flange widthbf
2in
Thicknesst
0.0346in
Inside bend radiusri
0.07642in

Mass and area

Mass per lengthm
1.109lb/ft
Cross-sectional areaA
0.3259in²
Outside perimeterP
18.91in

Strong axis x–x

Moment of inertiaIx
1.518in⁴
Elastic section modulusSx
0.5451in³
Plastic section modulusZx
0.6369in³
Radius of gyrationrx
2.158in

Weak axis y–y

Moment of inertiaIy
0.123in⁴
Elastic section modulusSy
0.07859in³
Plastic section modulusZy
0.1368in³
Radius of gyrationry
0.6144in

Torsion and stability

Torsional constantJ
0.0001296in⁴

Centers

Centroidx̄
0.4347in

Equivalents in other standards