Tracks (T)

550T125-97

Standard: AISI S200 / SFIASource: Calculated (exact engine)
Geometry derived from the standard designation (SFIA / AISI S200): depth, flange, lip, design thickness and inside radius. Gross (not effective) properties.
xybf = 1.25d = 5.703t = 0.1017t = 0.1017
Cross-section, to scaledimensions in inches

Dimensions

Depthd
5.703in
Flange widthbf
1.25in
Thicknesst
0.1017in
Inside bend radiusri
0.1525in

Mass and area

Mass per lengthm
2.708lb/ft
Cross-sectional areaA
0.7958in²
Outside perimeterP
15.85in

Strong axis x–x

Moment of inertiaIx
3.262in⁴
Elastic section modulusSx
1.144in³
Plastic section modulusZx
1.431in³
Radius of gyrationrx
2.024in

Weak axis y–y

Moment of inertiaIy
0.09039in⁴
Elastic section modulusSy
0.08907in³
Plastic section modulusZy
0.1578in³
Radius of gyrationry
0.337in

Torsion and stability

Torsional constantJ
0.002708in⁴

Centers

Centroidx̄
0.2351in

Equivalents in other standards