UPE – parallel-flange channels

UPE 200

Standard: EN 10365:2017Source: Geometry: Steel Section Database (MIT) — calculated properties (exact engine)
xybf = 80d = 200tf = 11tf = 11tw = 6tw = 6
Cross-section, to scaledimensions in mm

Dimensions

Depthd
200mm
Flange widthbf
80mm
Web thicknesstw
6mm
Flange thicknesstf
11mm
Root radiusr
13mm

Mass and area

Mass per lengthm
22.77kg/m
Cross-sectional areaA
2,901mm²
Outside perimeterP
696.8mm

Strong axis x–x

Moment of inertiaIx
19.0910⁶ mm⁴
Elastic section modulusSx
190.910³ mm³
Plastic section modulusZx
220.110³ mm³
Radius of gyrationrx
81.13mm

Weak axis y–y

Moment of inertiaIy
1.87310⁶ mm⁴
Elastic section modulusSy
34.4310³ mm³
Plastic section modulusZy
62.210³ mm³
Radius of gyrationry
25.41mm

Torsion and stability

Torsional constantJ
88.8810³ mm⁴

Centers

Centroidx̄
25.6mm

Equivalents in other standards