UPE – parallel-flange channels

UPE 220

Standard: EN 10365:2017Source: Geometry: Steel Section Database (MIT) — calculated properties (exact engine)
xybf = 85d = 220tf = 12tf = 12tw = 6.5tw = 6.5
Cross-section, to scaledimensions in mm

Dimensions

Depthd
220mm
Flange widthbf
85mm
Web thicknesstw
6.5mm
Flange thicknesstf
12mm
Root radiusr
13mm

Mass and area

Mass per lengthm
26.58kg/m
Cross-sectional areaA
3,387mm²
Outside perimeterP
755.8mm

Strong axis x–x

Moment of inertiaIx
26.8210⁶ mm⁴
Elastic section modulusSx
243.910³ mm³
Plastic section modulusZx
281.510³ mm³
Radius of gyrationrx
89mm

Weak axis y–y

Moment of inertiaIy
2.46410⁶ mm⁴
Elastic section modulusSy
42.5110³ mm³
Plastic section modulusZy
76.8810³ mm³
Radius of gyrationry
26.98mm

Torsion and stability

Torsional constantJ
120.510³ mm⁴

Centers

Centroidx̄
27.03mm

Equivalents in other standards